idw – Informationsdienst Wissenschaft

Nachrichten, Termine, Experten

Grafik: idw-Logo
Science Video Project
idw-Abo

idw-News App:

AppStore

Google Play Store



Instanz:
Teilen: 
29.01.2016 14:18

Suitable Protein Tags for Nanoscopy

Dr. Heike Conrad Presse- und Öffentlichkeitsarbeit
Exzellenzcluster und DFG-Forschungszentrum Mikroskopie im Nanometerbereich und Molekularphysiologie des Gehirns

    Scientists of the Göttingen Cluster of Excellence CNMPB and the EMBL describe efficient fluorescence tag for super-resolution microscopy. Published in ACS Nano.

    (cnmpb) Modern optical technologies such as super-resolution nanoscopy enable to exactly image small structures and molecular processes, therefore, providing a fascinating view into living cells. To visualize such processes in the nanometer range, cellular structures of interest have to be efficiently labeled. Fluorescent proteins are routinely used as convenient tags in conventional microscopy but their use for nanoscopy has been questioned. Scientists of the Göttingen Cluster of Excellence and DFG Research Center for Nanoscale Microscopy and Molecular Physiology of the Brain (CNMPB) and of the EMBL in Heidelberg now investigated the application of fluorescent protein tags on the organization of proteins. The findings of the team around Nobel Prize awardee Stefan W. Hell (Max Planck Institute for Biophysical Chemistry in Göttingen), Edward Lemke (EMBL, Heidelberg) and Silvio O. Rizzoli (University Medical Center Göttingen) proved the general use of fluorescent protein tags to be reliable tools in nanoscopy and for biomedical research. The results, recently published in ACS Nano, specially indicate fluorescence labeling based on unnatural amino acids to be a reliable alternative for labeling.

    Original publication: Vreja IC, Nikić I, Göttfert F, Bates M, Kröhnert K, Outeiro TF, Hell SW, Lemke EA, Rizzoli SO (2015) Super-resolution Microscopy of Clickable Amino Acids Reveals the Effects of Fluorescent Protein tagging on Protein Assemblies. ACS NANO, 9(11): 11034-41.

    Nanoscopy, or lens-based super-resolution microscopy, is a fairly new technique that enables to observe molecules and biomolecules with a resolution of 10-30 nm and to moreover analyze whole protein complexes. For their development and the implementation of super-resolution nanoscopy coauthor Stefan W. Hell, has been awarded with the Nobel Prize in Chemistry 2014 together with Betzig and William E. Moerner. For labeling and visualization procedures fluorescent protein tags are used. Due to their relatively large size these labels often tend to form clusters, thus, producing artifacts in nanoscopic recordings. „Regarding the ease of use and their compatibility, we are specially interested in genetically encoded fluorescent protein tags, which can be introduced into living cells by gene manipulation. Their use in nanoscopy should therefore be carefully investigated“, senior author Silvio O. Rizzoli explains. The scientists focused on 26 proteins, which are known to form various types of multi molecular arrangements and compared their nanoscale organization with or without fluorescent tag. The proteins were labeled with the smallest tag that is currently available, namely the unnatural amino acid propargyl-L-lysine (PRK) by insertion into the coding sequence of a target protein. For visualization with a super-resolution microscope, synthetic fluorophores were coupled to the PRK via “click chemistry”. This fast and selective organic reaction is an established a standard tool for labeling and modification of biomolecules.

    The researchers subsequently compared the nanoscopic organization of labeled and non-labeled proteins using ground-state depletion followed by individual molecule return microscopy (GSDIM) and stimulated emission depletion (STED) microscopy. Apart from six proteins that turned out to be slightly adversely affected, the FP-tagged and non-FP-tagged proteins formed similar molecular arrangements. In total, the scientists assessed the use of unnatural amino acids as suitable markers for nanoscopy. “Other research groups should now also test this labeling technique to see whether their target proteins are affected by the fluorescent protein tags or not,” first author Ingrid Vreja recommends. Together with their findings, the authors suggest an easily implementable detailed protocol that other researchers may use for testing and/or labeling their own proteins of interest.


    Image 1: Smaller probes can reveal more features in super-­resolution imaging. Transferrin receptor labeling with aptamers (left) better displays the shape of endosomes as irregular circular-­shaped compartments. In contrast, labeling with larger antibody probes (right) generates a staining pattern in which the shape of the endosomes is difficult to identify. Courtesy: Felipe Opazo / CNMPB.

    Image 2: GFP is an essential tool in fluorescence microscopy. Example of transfected cells that express VAMP4-­GFP. Cell nuclei are shown in blue. In the same sample, cells expressing the protein of interest labeled with a fluorescent protein show different phenotypes (compare the large bright areas around the cell nucleus on the right with the relatively homogeneous staining on the left). To tackle the question whether fluorescent protein tags affect the nanoscopic protein assemblies we resorted to super-­resolution microscopy. (from Vreja et
    al., 2015)


    Weitere Informationen:

    http://www.rizzoli-lab.de Homepage of the Department of Prof. Dr. Silvio O. Rizzoli
    http://www.cnmpb.de CNMPB - Cluster of Excellence and DFG Research Center for Nanoscale Microscopy and Molecular Physiology of the Brain


    Bilder

    The Göttingen team of scientists without Stefan W. Hell (from left to right) Tiago F. Outeirio, Silvio O. Rizzoli. Ingrid-Cristiana Vreja, Katharina Kröh-nert, Mark Bates, Fabian Göttfert.
    The Göttingen team of scientists without Stefan W. Hell (from left to right) Tiago F. Outeirio, Silv ...
    Rizzoli / CNMPB
    None

    Protein labeling with aptamers (left) better displays the shape of endosomes than labeling with larger antibody probes (right).
    Protein labeling with aptamers (left) better displays the shape of endosomes than labeling with larg ...
    Felipe Opazo / CNMPB
    None


    Anhang
    attachment icon Cells expressing the VAMP4 protein fused with a green fluorescent protein show different phenotypes.

    Merkmale dieser Pressemitteilung:
    Journalisten, Wissenschaftler
    Biologie, Chemie, Medizin
    überregional
    Forschungsergebnisse, Wissenschaftliche Publikationen
    Englisch


     

    The Göttingen team of scientists without Stefan W. Hell (from left to right) Tiago F. Outeirio, Silvio O. Rizzoli. Ingrid-Cristiana Vreja, Katharina Kröh-nert, Mark Bates, Fabian Göttfert.


    Zum Download

    x

    Protein labeling with aptamers (left) better displays the shape of endosomes than labeling with larger antibody probes (right).


    Zum Download

    x

    Hilfe

    Die Suche / Erweiterte Suche im idw-Archiv
    Verknüpfungen

    Sie können Suchbegriffe mit und, oder und / oder nicht verknüpfen, z. B. Philo nicht logie.

    Klammern

    Verknüpfungen können Sie mit Klammern voneinander trennen, z. B. (Philo nicht logie) oder (Psycho und logie).

    Wortgruppen

    Zusammenhängende Worte werden als Wortgruppe gesucht, wenn Sie sie in Anführungsstriche setzen, z. B. „Bundesrepublik Deutschland“.

    Auswahlkriterien

    Die Erweiterte Suche können Sie auch nutzen, ohne Suchbegriffe einzugeben. Sie orientiert sich dann an den Kriterien, die Sie ausgewählt haben (z. B. nach dem Land oder dem Sachgebiet).

    Haben Sie in einer Kategorie kein Kriterium ausgewählt, wird die gesamte Kategorie durchsucht (z.B. alle Sachgebiete oder alle Länder).