Higher efficiency through soft switching

Annette Siller Presse- und Öffentlichkeitsarbeit
Technologie Lizenz-Büro (TLB) der Baden-Württembergischen Hochschulen GmbH

    Efficiency and electro-magnetic compatibility - e.g. when feeding power into the mains supply - are major issues in the field of renewable energies . The power gained from photovoltaics or wind should be fed into the mains supply with the greatest efficiency possible and without any impact of electromagnetic interference on the environment.

    Professor Manfred W. Gekeler will present his S3L and SS3L inverters and comparative measurement results (EMC, efficiency) at the EMV Conference, Europe's leading exhibition for electromagnetic compatibility,

    Efficiency and electro-magnetic compatibility - e.g. when feeding power into the mains supply - are major issues in the field of renewable energies . The power gained from photovoltaics or wind should be fed into the mains supply with the greatest efficiency possible and without any impact of electromagnetic interference on the environment.

    Inverters are used to convert DC voltage into AC voltage and are deployed in electric drives, for feeding power of renewable sources (solar or wind) into the mains supply, for uninterruptible power supply or as active dynamic filter. Lately, the use of highly-promising 3-level pulse inverters have become increasingly popular. Today's conventional design inverters are of the hard-switching type. This type, however, produces switching losses which result in reduced efficiency.

    At the Konstanz University of Applied Sciences Prof. Dr.-Ing. Manfred W. Gekeler developed the S3L inverter which compensates for the disadvantages of the conventional hard-switching inverter. With this inverter, Prof. Gekeler has solved the problem of loss of energy in a simple way, namely by adding a snubber circuit. This circuit consists of merely a few simple, passive components and connects the topology of the multi-level inverter with the soft-switching technology.

    The "Soft-Switching Three Level (S3L) Inverter" distinguishes itself through its particularly high efficiency and favorable EMC behavior, even when used with standard Si power semiconductors (IGBT, IGCT, GTO). Now Prof. Gekeler has additionally developed a new variant of the switching, the SS3L inverter topology.

    In extensive tests carried out at the Konstanz University of Applied Sciences (HTWG), a 3-level inverter was reconfigured into the three variants H3L (conventional, hard-switching T-type version) S3L and SS3L and operated using different control methods and switching frequencies. Their interference voltages and efficiency were measured.

    The comparative measurements clearly confirmed the advantages of the two new inverter topologies – S3Land SS3L: In terms of efficiency, the two soft-switching inverter designs S3L and SS3L are significantly superior compared to the H3L inverter. Regarding EMC, the S3L inverter demonstrated clear advantages over the H3L inverter and the SS3L inverter even more so. Particularly when it came to using a specific operating type with a variable switching frequency, the SS3L inverter proved to be the best choice.

    Professor Manfred W. Gekeler will present the inverters and test results at the EMV Conference. The scientist, who teaches and does research at the Konstanz University of Applied Sciences, will present his S3L and SS3L inverters and comparative measurement results (EMC, efficiency) at Europe's leading exhibition for electromagnetic compatibility. The conference takes place in Duesseldorf from February 23-25, 2016. Prof. Gekeler will give a presentation on "power electronics“ on Wednesday, February 24, 2016 at 8:30 a.m. (session 2b).

    Patent applications for the invention have already been granted in major industrialized nations (DE, JP, KR, CN, USA, CA, EP).
    Licensing of this new technology is once again available for photovoltaics, engine control, uninterruptible power supply and wind power.
    The Konstanz University of Applied Sciences has entrusted Technologie-Lizenz-Büro (TLB) GmbH with the marketing of its innovation and the global economic implementation of this cutting-edge technology.

    For further information - including on licensing - please contact the TLB Innovation Manager Dipl.-Ing. Emmerich Somlo (somlo@tlb.de).


    Weitere Informationen:

    http://www.technologie-lizenz-buero.com/en/news/press-releases.html
    http://www.htwg-konstanz.de/Welcome-at-Hochschule-Konstanz.en


    Bilder

    Schematic circuit diagram of the soft-switching three level inverters (S3L and SS3L)
    Schematic circuit diagram of the soft-switching three level inverters (S3L and SS3L)
    Both figures: Prof. Manfred W. Gekeler, Konstanz University of Applied Sciences
    None

    EMC and efficiency comparison of H3L, S3L and SS3L inverters.
    EMC and efficiency comparison of H3L, S3L and SS3L inverters.

    None


    Merkmale dieser Pressemitteilung:
    Journalisten, Lehrer/Schüler, Studierende, Wirtschaftsvertreter, Wissenschaftler, jedermann
    Elektrotechnik, Energie, Maschinenbau, Umwelt / Ökologie
    überregional
    Forschungs- / Wissenstransfer, Wissenschaftliche Tagungen
    Englisch


     

    Schematic circuit diagram of the soft-switching three level inverters (S3L and SS3L)


    Zum Download

    x

    EMC and efficiency comparison of H3L, S3L and SS3L inverters.


    Zum Download

    x

    Hilfe

    Die Suche / Erweiterte Suche im idw-Archiv
    Verknüpfungen

    Sie können Suchbegriffe mit und, oder und / oder nicht verknüpfen, z. B. Philo nicht logie.

    Klammern

    Verknüpfungen können Sie mit Klammern voneinander trennen, z. B. (Philo nicht logie) oder (Psycho und logie).

    Wortgruppen

    Zusammenhängende Worte werden als Wortgruppe gesucht, wenn Sie sie in Anführungsstriche setzen, z. B. „Bundesrepublik Deutschland“.

    Auswahlkriterien

    Die Erweiterte Suche können Sie auch nutzen, ohne Suchbegriffe einzugeben. Sie orientiert sich dann an den Kriterien, die Sie ausgewählt haben (z. B. nach dem Land oder dem Sachgebiet).

    Haben Sie in einer Kategorie kein Kriterium ausgewählt, wird die gesamte Kategorie durchsucht (z.B. alle Sachgebiete oder alle Länder).