idw – Informationsdienst Wissenschaft

Nachrichten, Termine, Experten

Grafik: idw-Logo
Science Video Project
idw-Abo

idw-News App:

AppStore

Google Play Store



Instance:
Share on: 
03/18/2021 13:50

New microscopy method: MINSTED resolves fluorescent molecules with resolution at the nanometer scale

Dr. Carmen Rotte Presse- und Öffentlichkeitsarbeit
Max-Planck-Institut für biophysikalische Chemie

    Scientists working with Stefan Hell at the Max Planck Institute (MPI) for Biophysical Chemistry in Göttingen and the Heidelberg-based MPI for Medical Research have developed another light microscopy method, called MINSTED, which resolves fluorescently labeled details with molecular sharpness. With MINSTED, Nobel laureate Hell has come full circle.

    “A good 20 years ago, we fundamentally broke the diffraction resolution limit of fluorescence microscopy with STED. Until then, that was considered impossible,” says Hell. “Back then we dreamed: With STED we want to become so good that one day we will be able to separate individual molecules that are only a few nanometers apart. Now we've succeeded.” At that time, the STED principle amounted to a revolution in light microscopy. For this conceptual leap and subsequent developments, Hell received the Nobel Prize in Chemistry in 2014.

    In its original version, STED microscopy achieved a resolution of 20 to 30 nanometers (millionths of a millimeter) and was thus around ten times sharper than the light microscopes available up to that point. In 2016, Hell and his coworkers were able to further increase the resolution tenfold through a new method called MINFLUX nanoscopy. In that new approach, they combined an element from the STED principle with one from another light microscopic technique, PALM/STORM, and thus achieved a resolution of just a few nanometers for the first time. MINFLUX can truly make fluorescent molecules visible on molecular scales – it does not get any sharper.

    A new family of nanometer resolution microscopes

    Hell was convinced that MINFLUX would not remain the only molecular resolution method, but rather would represent the first member of a new family of techniques with this level of detail. With MINSTED, he and his coworkers are now showing this to be true. As the name suggests, MINSTED relies on the original STED principle even more than MINFLUX. Elaborating on this, Michael Weber, a PhD student in Hell’s laboratory and one of the developers of MINSTED, says: “This has advantages. Like MINFLUX, it achieves molecular resolution, but the background noise is lower. In addition, the resolution can now be adjusted almost continuously from 200 nanometers down to the molecular size – 1 nanometer.”

    With MINSTED, Hell is building on his breakthrough with STED more than 20 years ago and is extracting the full potential from this concept. “Microscopy on the molecular scale is here to stay. It is to be expected that MINSTED and MINFLUX will become widely used in the life sciences,” says the physicist.

    Switching the fluorescence of molecules on and off

    STED achieved what was previously unattainable, separately detecting molecules less than 200 nanometers apart, with a trick: Neighboring fluorescent features or molecules are switched on and off one after the other. To do this, a laser beam that excites the molecules is immediately followed by a second one, the so-called STED beam, which prevents the molecules from fluorescing. The STED beam, however, has a ‘hole’ in the middle. In other words, it is donut-shaped. Only the molecules in the middle of this donut beam can fluoresce. Thus, one always knows where the emitting molecules are. In practice, STED does not achieve molecular resolution because the donut-shaped fluorescence inhibition beam cannot be made so strong that only a single molecule can fit into the hole.

    For this reason in MINSTED, the fluorescent molecules are initially isolated by randomly switching them on through an independent photochemical switching process, rather than by the donut beam itself. The fluorescence-preventing STED donut beam is then used to locate the fluorescent molecules individually. Its hole serves as a reference point. “If the hole coincides with the molecule, the molecule glows most strongly and you can figure out precisely where it is, because the exact position of the STED donut beam is always known,” says Marcel Leutenegger, a postdoctoral researcher in Hell's department. “That’s why we gradually approach the molecules in a targeted fashion with the donut beam and can thus locate the fluorescent molecules with an accuracy of 1 to 3 nanometers, that is, the size of the molecules. In connection with the photochemical on and off switching, the resolution becomes molecular-scale.”


    Contact for scientific information:

    Prof. Dr. Stefan W. Hell
    Department of NanoBiophotonics
    phone: +49 551 201-2500
    e-mail: shell@gwdg.de


    Original publication:

    Michael Weber*, Marcel Leutenegger*, Stefan Stoldt, Stefan Jakobs, Tiberiu S. Mihaila, Alexey N. Butkevich, Stefan W. Hell:
    MINSTED fluorescence localization and nanoscopy. Nature Photonics (2021) https://doi.org/10.1038/s41566-021-00774-2
    (*equal contribution)


    More information:

    https://www.mpibpc.mpg.de/17698194/pr_2105 - Original press release
    https://www.mpibpc.mpg.de/hell − Website of Stefan Hell’s Department of NanoBiophotonics, Max Planck Institute for Biophysical Chemistry
    https://www.mr.mpg.de/departments/optical-nanoscopy − Website of Stefan Hell’s Department of Optical Nanoscopy, Max Planck Institute for Medical Research


    Images

    A comparison of different light microscopy techniques: STED (bottom left) improves the sharpness of detail drastically compared to conventional confocal microscopy (top left). MINSTED (right) achieves a resolution that is yet ten times higher.
    A comparison of different light microscopy techniques: STED (bottom left) improves the sharpness of ...

    © Michael Weber / Max Planck Institute for Biophysical Chemistry

    Michael Weber, Prof. Dr. Stefan Hell, and Dr. Marcel Leutenegger (from left)
    Michael Weber, Prof. Dr. Stefan Hell, and Dr. Marcel Leutenegger (from left)

    © Irene Böttcher-Gajewski / Max Planck Institute for Biophysical Chemistry


    Criteria of this press release:
    Journalists, Scientists and scholars, Students
    Biology, Physics / astronomy
    transregional, national
    Research results, Scientific Publications
    English


     

    A comparison of different light microscopy techniques: STED (bottom left) improves the sharpness of detail drastically compared to conventional confocal microscopy (top left). MINSTED (right) achieves a resolution that is yet ten times higher.


    For download

    x

    Michael Weber, Prof. Dr. Stefan Hell, and Dr. Marcel Leutenegger (from left)


    For download

    x

    Help

    Search / advanced search of the idw archives
    Combination of search terms

    You can combine search terms with and, or and/or not, e.g. Philo not logy.

    Brackets

    You can use brackets to separate combinations from each other, e.g. (Philo not logy) or (Psycho and logy).

    Phrases

    Coherent groups of words will be located as complete phrases if you put them into quotation marks, e.g. “Federal Republic of Germany”.

    Selection criteria

    You can also use the advanced search without entering search terms. It will then follow the criteria you have selected (e.g. country or subject area).

    If you have not selected any criteria in a given category, the entire category will be searched (e.g. all subject areas or all countries).