idw – Informationsdienst Wissenschaft

Nachrichten, Termine, Experten

Grafik: idw-Logo
Grafik: idw-Logo

idw - Informationsdienst
Wissenschaft

Science Video Project
idw-Abo

idw-News App:

AppStore

Google Play Store



Instance:
Share on: 
04/05/2022 14:06

Technical rules and regulations impart knowledge and promote confidence in optical coherence tomography

Susanne Krause Externe und interne Kommunikation
Fraunhofer-Institut für Produktionstechnologie IPT

    Optical coherence tomography (OCT) is a new imaging technique that generates high-resolution cross-sectional images of transparent and semitransparent media. It is used both in industrial metrology, for example in component monitoring, and in biomedical diagnostics, such as ophthalmology or tissue diagnostics. Companies and research institutes focusing on industrial metrology and medical technology also expect a wide range of other fields of application. They cooperate in the VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik (GMA) in an expert committee on OCT and have now published a first draft guideline with standardized process descriptions.

    Bringing together expertise from industry and research to jointly publish a standardized set of rules for OCT and thus open the way for further OCT application fields in the future - that is the goal of GMA's Technical Committee 8.19 "Optical Coherence Tomography". This is because the comparatively new measurement method has not yet been described in a generally valid manner, and various procedures and performance characteristics have not yet been standardized. Thus, the comparability of different OCT systems is not yet given and a wider dissemination is limited. This is to change through the guideline work of the technical committee: "Knowledge of and confidence in OCT are to be promoted through a general technical set of rules. To this end, we have now defined terms and measurement methods for performance parameters and described typical process variants as a first step," explains Niels König, head of the Production Measurement Technology department at the Fraunhofer IPT and chairman of the expert committee.

    Non-contact and high-resolution imaging - from biomedicine to industry

    Originally used in ophthalmology, OCT is a measurement technique based on short-coherent interferometry for non-contact and high-resolution imaging of tomographic cross-sectional images. It has a penetration depth of several millimeters and a resolving power in the single-digit micrometer range. In medical diagnostics, OCT can be used to examine organic tissue, such as tumor tissue, at a very early stage of disease, either intraoperatively or in vitro. But OCT is also used in industry thanks to its universal properties in material and defect testing, for example in plastic products. In the case of opaque materials into which the light cannot penetrate, for example metal, OCT is used for surface and distance measurement.

    Now, the first work results of the new technical committee on OCT are available in the form of the draft guideline VDI/VDE 5565 Part 1. The draft describes the OCT procedures and defines the necessary terms. In order to reach as much of the OCT community as possible, the draft has already been published bilingually in German and English. The draft can be commented on by objection until July 31, 2022. After the objections have been dealt with, the valid guideline will then be published. The committee is already working on VDI/VDE 5565 Part 2 on "Signal processing and data evaluation". The metrological characterization of OCT systems is on the roadmap for further guideline projects.

    For further information, please contact the GMA office:

    VDI/VDE Society
    Measurement and automation technology (GMA)
    Erik Marquardt
    Phone +49 211 6214-373
    marquardt@vdi.de
    www.vdi.de/5565


    Contact for scientific information:

    Dipl.-Phys. Niels König
    Head of department "Production metrology"

    Fraunhofer Institute for Production Technology IPT
    Steinbachstr. 17
    52074 Aachen, Germany
    Phone +49 241 8904-113
    niels.koenig@ipt.fraunhofer.de
    www.ipt.fraunhofer.de


    More information:

    https://www.ipt.fraunhofer.de/en/Press/Pressreleases/220328-technical-rules-and-...


    Images

    First OCT guideline proposal with standardized procedure descriptions.
    First OCT guideline proposal with standardized procedure descriptions.

    © Fraunhofer IPT


    Criteria of this press release:
    Business and commerce, Journalists, Scientists and scholars
    Biology, Electrical engineering, Materials sciences, Mechanical engineering, Medicine
    transregional, national
    Cooperation agreements, Transfer of Science or Research
    English


     

    Help

    Search / advanced search of the idw archives
    Combination of search terms

    You can combine search terms with and, or and/or not, e.g. Philo not logy.

    Brackets

    You can use brackets to separate combinations from each other, e.g. (Philo not logy) or (Psycho and logy).

    Phrases

    Coherent groups of words will be located as complete phrases if you put them into quotation marks, e.g. “Federal Republic of Germany”.

    Selection criteria

    You can also use the advanced search without entering search terms. It will then follow the criteria you have selected (e.g. country or subject area).

    If you have not selected any criteria in a given category, the entire category will be searched (e.g. all subject areas or all countries).