idw – Informationsdienst Wissenschaft

Nachrichten, Termine, Experten

Grafik: idw-Logo
Grafik: idw-Logo

idw - Informationsdienst
Wissenschaft

Science Video Project
idw-Abo

idw-News App:

AppStore

Google Play Store



Instance:
Share on: 
10/27/2022 10:09

Miniaturized pump laser modules for more cost-effective laser systems in ophthalmology

Petra Immerz Pressestelle
Ferdinand-Braun-Institut gGmbH Leibniz-Institut für Höchstfrequenztechnik

    Scientists at the Berlin-based Ferdinand-Braun-Institut (FBH) have developed prototypes of miniaturized and robust laser modules for ophthalmology. They can be used as reasonably priced pump sources in laser systems to treat retinal detachments. In addition, their wavelength can be precisely adjusted to the respective application.

    Detachment of the retina in the eye can lead to visual impairment and even blindness. Laser coagulation is a well-established method to treat holes or fissures in the retina using laser points. This technique is used to deal with diseases such as diabetic retinopathy and age-related macular degeneration. However, the systems currently utilized are rather expensive and limited to a few laser wavelengths.

    This might be changed by semiconductor-based, particularly efficient and reliable laser sources from the Ferdinand-Braun-Institut. They can be flexibly adjusted to the optimal wavelength and realized cost efficiently. Only recently, FBH scientists have developed miniaturized and robust laser sources emitting in the near-infrared (NIR) wavelength range with high spectral radiance and a performance well suited for industrial applications. The sources each consist of a pump laser whose light from the NIR spectral range can then be converted using a nonlinear crystal – this frequency doubling (Second Harmonic Generation – SHG) halves the wavelength. As a result, the laser then emits in the visible spectral range. Current systems for laser coagulation use specifically the wavelengths 532 nm and 577 nm. Therefore, FBH pump modules target these established wavelengths in the yellow-green spectral range. Lasers emitting at 577 nm are particularly interesting for ophthalmology since the oxygen-rich blood pigment, known as oxyhemoglobin, absorbs most strongly at this wavelength.

    The unique combination of miniaturized light modules as pump sources followed by highly efficient SHG stages makes it possible to cover the entire spectrum from 400 nm to 600 nm. In contrast, the wavelengths of previous solid-state laser systems are limited to the 532 nm, 561 nm, 577 nm and 586 nm laser lines. Moreover, the laser diodes and amplifiers can be manufactured in large quantities on wafers, thus reducing costs. For example, 400 of these active components fit on a 3-inch wafer with a diameter of 7.6 cm.

    The laser source in detail

    The spectrally narrowband pump sources at 1154 nm and 1064 nm provide very high optical output powers with an excellent beam quality. Subsequent frequency doubling into the yellow-green spectral range is thus simplified. This reduces cost and weight compared to the more complex laser sources used for laser coagulation to date. Portable, correspondingly flexible use of the systems in an outpatient environment would be possible as well.

    To demonstrate the suitability of the light modules as pump sources, FBH scientists have developed module prototypes with separate laser beam generation (Master Oscillator – MO) and power amplification (Power Amplifier – PA). A commercial miniaturized isolator was integrated between the two components to completely protect the laser (MO) from external feedback. This can be very high (> 1%) in SHG crystals with waveguides and can significantly interfere with the MO. Despite the small footprint of only 25 mm x 25 mm, the modules achieve optical output powers of more than 8 watts in continuous wave (CW) mode at 1064 nm as well as 1156 nm. At the same time, they achieve a very good beam quality of M2 < 2 and a spectral linewidth of < 5 MHz. This performance can also be transferred to other wavelengths.


    More information:

    https://www.fbh-berlin.de/en/transfer-services/modules-systems/life-sciences-mea... Diode Lasers for Life Sciences, Measurements & Displays


    Images

    Miniaturized and robust pump laser module for ophthalmology
    Miniaturized and robust pump laser module for ophthalmology
    Petra Immerz
    FBH/P. Immerz


    Criteria of this press release:
    Business and commerce, Journalists, Scientists and scholars, Students
    Medicine, Physics / astronomy
    transregional, national
    Transfer of Science or Research
    English


     

    Help

    Search / advanced search of the idw archives
    Combination of search terms

    You can combine search terms with and, or and/or not, e.g. Philo not logy.

    Brackets

    You can use brackets to separate combinations from each other, e.g. (Philo not logy) or (Psycho and logy).

    Phrases

    Coherent groups of words will be located as complete phrases if you put them into quotation marks, e.g. “Federal Republic of Germany”.

    Selection criteria

    You can also use the advanced search without entering search terms. It will then follow the criteria you have selected (e.g. country or subject area).

    If you have not selected any criteria in a given category, the entire category will be searched (e.g. all subject areas or all countries).