idw – Informationsdienst Wissenschaft

Nachrichten, Termine, Experten

Grafik: idw-Logo
Grafik: idw-Logo

idw - Informationsdienst
Wissenschaft

Science Video Project
idw-Abo

idw-News App:

AppStore

Google Play Store



Instance:
Share on: 
11/25/2024 09:51

21-ton magnet installed in new MESA particle accelerator

Dr. Victoria Durant Kommunikation und Presse
Johannes Gutenberg-Universität Mainz

    Superconducting core component for international P2 experiment installed in underground hall at a depth of ten meters

    One of the flagship projects of the PRISMA+ Cluster of Excellence at Johannes Gutenberg University Mainz (JGU) is the construction of the new energy-recovering particle accelerator MESA (Mainz Energy-recovering Superconducting Accelerator), which will enable experiments with unprecedented precision in the future. One of the main experiments at MESA, P2, will play a key role in researching the "new physics" - physics beyond the standard model of particle physics - by measuring the so-called weak mixing angle.
    The central component of the P2 experiment, a superconducting magnet coil with a diameter of four meters and a weight of 21 tons, has now been delivered to the JGU campus and installed in the MESA particle accelerator. The magnet was manufactured in Vannes, France, and delivered to Mainz last Thursday. "We have been working together with the company SigmaPhi for almost five years to overcome the challenges and implement the state-of-the-art design for our experiment, " says Professor Frank Maas, spokesperson for the P2 experiment, which is currently being set up by a collaboration of physicists from Germany, France, Canada and the USA. "Such a solenoid magnet is being used for experiments of this kind for the first time. Its large diameter makes it possible to record particularly high particle rates. However, the size of the magnet also posed a particular challenge in terms of design and production."

    At around four degrees above absolute zero (at approx. minus 269 °C), the coil loses its electrical resistance and becomes superconducting. To reach these low temperatures, it is operated in a vacuum inside a cryostat and cooled with liquid helium. It was delivered by special transport from Vannes in Brittany and transported by a special mobile crane with a beam of more than 30 meters in length through an opening in the roof of the new MESA building to the accelerator level ten meters below ground. There it was installed in an iron yoke weighing around one hundred tons.

    One magnet, two main tasks

    The main aim of the P2 experiment is to determine the weak mixing angle, a measure of the relative strength of the weak and electromagnetic interactions. The supplied magnet plays a key role in determining this fundamental quantity of the standard model and has two crucial functions. Firstly, it is used to focus the elastically scattered electrons onto the detectors whose signals are analyzed by the P2 team. Secondly, it is used to deflect and suppress background events that are not relevant for the data analysis. A precise experimental determination of the weak mixing angle in comparison with equally precise theoretical calculations will make it possible to test the standard model. Deviations between theory and experiment would be an indication of new particles or forces beyond those known from the Standard Model and an experimental indication of the nature of dark matter.

    A new building for MESA

    Part of the underground halls was rebuilt with the ‘Center for Fundamental Physics’ (CFP). The CFP forms the structural framework for central PRISMA+ research projects, the most important of which is MESA. As part of CFP I, existing underground experimental halls of the Institute of Nuclear Physics were extended by a hall covering around 600 square meters. The existing halls were modernized and partially converted. These include the halls of the Mainz Microtron Electron Accelerator (MAMI), which has been in successful operation since 1979. The new MESA hall is directly attached to it, so that the existing beam catcher is integrated into the construction project. The halls are connected via large wall openings in order to create sufficient space for the MESA accelerator and the associated scientific experiments.


    Contact for scientific information:

    Professor Dr. Frank Maas
    PRISMA+ Cluster of Excellence/ GSI Helmholtzzentrum für Schwerionenforschung/ Helmholtz Institute Mainz (HIM)
    Institute for Nuclear Physics
    Johannes Gutenberg University Mainz
    55099 Mainz, Germany
    email: maas@him.uni-mainz.de
    https://www.kernphysik.uni-mainz.de/univ-prof-dr-frank-maas/


    More information:

    https://press.uni-mainz.de/new-crc-1660-hadrons-and-nuclei-as-discovery-tools/ – Press release “New CRC 1660: Hadrons and Nuclei as Discovery Tools” (31.05.2024)
    https://press.uni-mainz.de/erc-advanced-grant-for-maarten-boonekamp-in-collabora... – Press release “ERC Advanced Grant for Maarten Boonekamp in collaboration with Jens Erler and Frank Maas” (11.04.2024)


    Images

    Der 21 Tonnen schwere Magnet für den neuen Mainzer Teilchenbeschleuniger MESA wird durch das Dach des Centrums für Fundamentale Physik in die unterirdische Halle in zehn Metern Tiefe eingebracht.
    Der 21 Tonnen schwere Magnet für den neuen Mainzer Teilchenbeschleuniger MESA wird durch das Dach de ...
    Twain Wegner
    Twain Wegner


    Criteria of this press release:
    Journalists, Scientists and scholars
    Physics / astronomy
    transregional, national
    Miscellaneous scientific news/publications
    English


     

    Help

    Search / advanced search of the idw archives
    Combination of search terms

    You can combine search terms with and, or and/or not, e.g. Philo not logy.

    Brackets

    You can use brackets to separate combinations from each other, e.g. (Philo not logy) or (Psycho and logy).

    Phrases

    Coherent groups of words will be located as complete phrases if you put them into quotation marks, e.g. “Federal Republic of Germany”.

    Selection criteria

    You can also use the advanced search without entering search terms. It will then follow the criteria you have selected (e.g. country or subject area).

    If you have not selected any criteria in a given category, the entire category will be searched (e.g. all subject areas or all countries).