08/14/2018 10:04

Can radar replace stethoscopes?

Dr. Susanne Langer Kommunikation und Presse
Friedrich-Alexander-Universität Erlangen-Nürnberg

    In conjunction with researchers at Brandenburg University of Technology (BTU) in Cottbus and the Department of Palliative Medicine at Universitätsklinikum Erlangen, electronic engineers at Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU) have developed a procedure for reliably detecting and diagnosing heart sounds using radar. In future, mobile radar devices could replace conventional stethoscopes and permanent touch-free monitoring of patients’ vital functions could be possible using stationary radar devices. The results have now been published in the renowned journal ‘Scientific Reports’.

    Along with a white coat, a stethoscope is the hallmark of doctors everywhere. Stethoscopes are used to diagnose the noises produced by the heart and lungs. Used in the conventional way, vibrations from the surface of the body are transmitted to a membrane in the chest-piece and then to the user’s eardrum where they are perceived as sounds. Acoustic stethoscopes are comparatively inexpensive and have been used reliably for several decades, but they have one drawback. The diagnosis of heart murmurs, such as the assessment of heart valve function, is carried out subjectively and is directly dependent on the experience of the doctor conducting the examination.

    Radar can measure heart sounds

    In a joint project funded by the Federal Ministry of Education and Research, FAU researchers at the Institute of Electronics Engineering (LTE) have now developed a procedure that could eventually replace conventional phonocardiology. Using a six-port continuous wave radar system, they measured the vibrations on the skin caused by the heartbeat. ‘In principle, we’re using a similar method to detecting speed in road traffic,’ explains Christoph Will, a doctoral candidate at LTE. ‘During this process, a radar wave is aimed at the surface of an object and reflected. If the object moves, the phase of the reflecting wave changes. This is used to calculate the strength and frequency of the movement – of the chest in our case.’ In contrast to radar systems for traffic monitoring, the biomedical radar system can detect changes in movement that measure a few micrometres, which is an important prerequisite to diagnosing even the smallest anomalies such as insufficiency, stenoses or heart valves that do not close properly.

    As reliable as established measuring methods

    Initial tests were very successful. The test patients were examined in various states of activity such as while resting and after sports and their heart sounds were detected. A direct comparison between the radar system and conventional standard instruments with a digital stethoscope and an electrocardiograph (ECG) showed a very high correlation. ‘While diagnosing S1, which is the first heart sound, for example, we achieved a correlation of 92 percent with the ECG,’ says Kilin Shi, who is also a doctoral candidate at LTE. ‘The correlation was 83 percent in a direct comparison of the signal shapes with the digital stethoscope. That’s absolutely reliable.’ The researchers say that the slight deviations are caused by the fact that measurements using the radar system and the reference systems cannot be carried out simultaneously on exactly the same place on the body. In addition, the radar system measures a surface area and not a single spot like the stethoscope, which is also a reason for the varying measurement values.

    Touch-free and objective

    The FAU researchers are optimistic that mobile radar systems could replace conventional stethoscopes in diagnosing heart function in the near future. A significant advantage offered by radar is the fact that the values are recorded digitally and are thus not subjective allowing human error to be increasingly ruled out during the diagnosis of anomalies or diseases. Using biomedical radar systems for automated prophylactic examinations for example in doctors’ waiting rooms, at work, or at home, is also feasible.

    The researchers are already working on another project for monitoring the vital functions of patients who are seriously ill using stationary radar systems around the clock and without disruptive cables. ‘Touch-free and therefore stress-free measurement of vital parameters such as heart sounds has the potential to revolutionise clinical care and research, for example, in palliative medicine,’ explains Prof. Dr. Christoph Ostgathe, Head of Palliative Medicine at Universitätsklinikum Erlangen at FAU and co-author of the study. ‘For example, we could inform relatives of terminally ill patients more quickly at the beginning of the dying phase, as the radar system immediately detects any changes in patients’ health. It would also be possible to detect any painful symptoms in patients who cannot communicate’.


    Contact for scientific information:

    Technical details:
    Kilin Shi
    +49 9131 8567733
    kilin.shi@fau.de

    Medical information:
    Prof. Dr. Christoph Ostgathe
    +49 9131 8534063
    christoph.ostgathe@uk-erlangen.de


    Original publication:

    ‘Scientific Reports’: ‘Radar-Based Heart Sound Detection’, https://doi.org/10.1038/s41598-018-29984-5


    Images

    Electronic engineers at FAU have developed a procedure for reliably detecting and diagnosing heart sounds using radar.
    Electronic engineers at FAU have developed a procedure for reliably detecting and diagnosing heart s ...
    Image: FAU/Kilin Shi
    None

    Researchers at FAU’s Institute of Electronics Engineering have developed a radar system which enables touch-free monitoring of heart sounds. The red beams show where the measurement is being made.
    Researchers at FAU’s Institute of Electronics Engineering have developed a radar system which enable ...
    Image: Kilin Shi
    None


    Criteria of this press release:
    Journalists
    Electrical engineering, Medicine, Nutrition / healthcare / nursing
    transregional, national
    Research results, Scientific Publications
    English


     

    Electronic engineers at FAU have developed a procedure for reliably detecting and diagnosing heart sounds using radar.


    For download

    x

    Researchers at FAU’s Institute of Electronics Engineering have developed a radar system which enables touch-free monitoring of heart sounds. The red beams show where the measurement is being made.


    For download

    x

    Help

    Search / advanced search of the idw archives
    Combination of search terms

    You can combine search terms with and, or and/or not, e.g. Philo not logy.

    Brackets

    You can use brackets to separate combinations from each other, e.g. (Philo not logy) or (Psycho and logy).

    Phrases

    Coherent groups of words will be located as complete phrases if you put them into quotation marks, e.g. “Federal Republic of Germany”.

    Selection criteria

    You can also use the advanced search without entering search terms. It will then follow the criteria you have selected (e.g. country or subject area).

    If you have not selected any criteria in a given category, the entire category will be searched (e.g. all subject areas or all countries).