idw – Informationsdienst Wissenschaft

Nachrichten, Termine, Experten

Grafik: idw-Logo
Science Video Project
idw-Abo

idw-News App:

AppStore

Google Play Store



Instance:
Share on: 
05/26/2020 09:00

Increased Usability and Precision in Vascular Imaging

Kurt Bodenmüller Kommunikation
Universität Zürich

    Researchers at the University of Zurich have developed a new X-ray contrast agent. The contrast agent is easier to use and distributes into all blood vessels more reliably, increasing the precision of vascular imaging. This reduces the number of animals required in research experiments.

    Various diseases in humans and animals – such as tumors, strokes or chronic kidney disease – damage the blood vessels. Capillaries, the smallest blood vessels in the body, are particularly affected. The large surface area of the capillary network enables oxygen to be exchanged between the blood and the surrounding tissue, such as the muscles when we exercise or the brain when we think.

    Revealing the vascular structure

    For the diagnosis and treatment of cardiovascular and other diseases, it is important to know the three-dimensional structure of blood vessels. This knowledge of the exact anatomy of the capillaries in humans and animals is also crucial for basic research. It enables researchers to investigate diseases that attack the blood vessels and evaluate new treatments. Researchers at the University of Zurich (UZH), the National Centre of Competence in Research Kidney.CH and the Biomaterials Science Center of the University of Basel have now developed a novel X-ray contrast agent called “XlinCA”, with which capillaries can be made visible much more precisely using computer tomography.

    Previous methods often faulty

    Previously, contrast agents were added to polymerizing plastic resins before they were injected into the blood vessels of euthanized animals. However, it is very difficult to completely fill out the delicate capillaries in various organs with viscous resins. “Without years of experience using the right injection techniques, the capillaries are often only partially filled, or missing entirely. Up to a quarter of the resulting images are therefore unusable,” says Willy Kuo, a postdoctoral researcher at the Institute of Physiology of UZH. By using “XlinCA” instead of other contrast agents, up to 25 percent fewer animals would be needed for experiments, states Kuo.

    The basic problem with conventional methods is that plastic and water do not mix. This results in water inclusions where the contrast agent is absent, which causes disconnected vessel segments on the X-ray image. While the water-soluble X-ray contrast agents used in medicine may not have this problem, they cannot be solidified and leak through blood vessel walls into the surrounding tissue within minutes.

    Optimum results thanks to custom contrast agent

    Contrast agents for medical use in humans consist of small molecules and are relatively simple to produce. “A custom contrast agent for ex vivo use was significantly more difficult to synthesize, since it is made up of polymers – molecules bonded together in long chains,” says Bernhard Spingler, professor at UZH’s Department of Chemistry. “XlinCA” has several advantages over previously used X-ray contrast agents: It is easy to use and enables complete and uninterrupted vascular imaging. It also allows multiple organs or even whole animals such as mice to be examined at the same time.


    Contact for scientific information:

    Prof. Dr. Vartan Kurtcuoglu
    Institute of Physiology
    University of Zurich
    Phone: +41 44 635 50 55
    E-mail: vartan.kurtcuoglu@uzh.ch

    Prof. Dr. Bernhard Spingler
    Department of Chemistry
    University of Zurich
    Phone: +41 44 635 46 56
    E-mail: spingler@chem.uzh.ch


    Original publication:

    Ngoc An Le, Willy Kuo, Bert Müller, Vartan Kurtcuoglu, Bernhard Spingler. Crosslinkable polymeric contrast agent for high-resolution X-ray imaging of the vascular system. Chemical Communications. 27 April 2020. DOI: 10.1039/C9CC09883F


    More information:

    https://www.media.uzh.ch/en/Press-Releases/2020/Contrast-Agent.html


    Images

    3D imaging of the blood vessels of a mouse head using X-ray computer tomography and the newly developed contrast agent "XlinCA".
    3D imaging of the blood vessels of a mouse head using X-ray computer tomography and the newly develo ...
    Willy Kuo, University of Zurich


    Criteria of this press release:
    Journalists
    Biology, Chemistry, Medicine
    transregional, national
    Research results, Scientific Publications
    English


     

    3D imaging of the blood vessels of a mouse head using X-ray computer tomography and the newly developed contrast agent "XlinCA".


    For download

    x

    Help

    Search / advanced search of the idw archives
    Combination of search terms

    You can combine search terms with and, or and/or not, e.g. Philo not logy.

    Brackets

    You can use brackets to separate combinations from each other, e.g. (Philo not logy) or (Psycho and logy).

    Phrases

    Coherent groups of words will be located as complete phrases if you put them into quotation marks, e.g. “Federal Republic of Germany”.

    Selection criteria

    You can also use the advanced search without entering search terms. It will then follow the criteria you have selected (e.g. country or subject area).

    If you have not selected any criteria in a given category, the entire category will be searched (e.g. all subject areas or all countries).