idw – Informationsdienst Wissenschaft

Nachrichten, Termine, Experten

Grafik: idw-Logo
Science Video Project
idw-Abo

idw-News App:

AppStore

Google Play Store



Instanz:
Teilen: 
26.05.2020 09:00

Increased Usability and Precision in Vascular Imaging

Kurt Bodenmüller Kommunikation
Universität Zürich

    Researchers at the University of Zurich have developed a new X-ray contrast agent. The contrast agent is easier to use and distributes into all blood vessels more reliably, increasing the precision of vascular imaging. This reduces the number of animals required in research experiments.

    Various diseases in humans and animals – such as tumors, strokes or chronic kidney disease – damage the blood vessels. Capillaries, the smallest blood vessels in the body, are particularly affected. The large surface area of the capillary network enables oxygen to be exchanged between the blood and the surrounding tissue, such as the muscles when we exercise or the brain when we think.

    Revealing the vascular structure

    For the diagnosis and treatment of cardiovascular and other diseases, it is important to know the three-dimensional structure of blood vessels. This knowledge of the exact anatomy of the capillaries in humans and animals is also crucial for basic research. It enables researchers to investigate diseases that attack the blood vessels and evaluate new treatments. Researchers at the University of Zurich (UZH), the National Centre of Competence in Research Kidney.CH and the Biomaterials Science Center of the University of Basel have now developed a novel X-ray contrast agent called “XlinCA”, with which capillaries can be made visible much more precisely using computer tomography.

    Previous methods often faulty

    Previously, contrast agents were added to polymerizing plastic resins before they were injected into the blood vessels of euthanized animals. However, it is very difficult to completely fill out the delicate capillaries in various organs with viscous resins. “Without years of experience using the right injection techniques, the capillaries are often only partially filled, or missing entirely. Up to a quarter of the resulting images are therefore unusable,” says Willy Kuo, a postdoctoral researcher at the Institute of Physiology of UZH. By using “XlinCA” instead of other contrast agents, up to 25 percent fewer animals would be needed for experiments, states Kuo.

    The basic problem with conventional methods is that plastic and water do not mix. This results in water inclusions where the contrast agent is absent, which causes disconnected vessel segments on the X-ray image. While the water-soluble X-ray contrast agents used in medicine may not have this problem, they cannot be solidified and leak through blood vessel walls into the surrounding tissue within minutes.

    Optimum results thanks to custom contrast agent

    Contrast agents for medical use in humans consist of small molecules and are relatively simple to produce. “A custom contrast agent for ex vivo use was significantly more difficult to synthesize, since it is made up of polymers – molecules bonded together in long chains,” says Bernhard Spingler, professor at UZH’s Department of Chemistry. “XlinCA” has several advantages over previously used X-ray contrast agents: It is easy to use and enables complete and uninterrupted vascular imaging. It also allows multiple organs or even whole animals such as mice to be examined at the same time.


    Wissenschaftliche Ansprechpartner:

    Prof. Dr. Vartan Kurtcuoglu
    Institute of Physiology
    University of Zurich
    Phone: +41 44 635 50 55
    E-mail: vartan.kurtcuoglu@uzh.ch

    Prof. Dr. Bernhard Spingler
    Department of Chemistry
    University of Zurich
    Phone: +41 44 635 46 56
    E-mail: spingler@chem.uzh.ch


    Originalpublikation:

    Ngoc An Le, Willy Kuo, Bert Müller, Vartan Kurtcuoglu, Bernhard Spingler. Crosslinkable polymeric contrast agent for high-resolution X-ray imaging of the vascular system. Chemical Communications. 27 April 2020. DOI: 10.1039/C9CC09883F


    Weitere Informationen:

    https://www.media.uzh.ch/en/Press-Releases/2020/Contrast-Agent.html


    Bilder

    3D imaging of the blood vessels of a mouse head using X-ray computer tomography and the newly developed contrast agent "XlinCA".
    3D imaging of the blood vessels of a mouse head using X-ray computer tomography and the newly develo ...
    Willy Kuo, University of Zurich


    Merkmale dieser Pressemitteilung:
    Journalisten
    Biologie, Chemie, Medizin
    überregional
    Forschungsergebnisse, Wissenschaftliche Publikationen
    Englisch


     

    3D imaging of the blood vessels of a mouse head using X-ray computer tomography and the newly developed contrast agent "XlinCA".


    Zum Download

    x

    Hilfe

    Die Suche / Erweiterte Suche im idw-Archiv
    Verknüpfungen

    Sie können Suchbegriffe mit und, oder und / oder nicht verknüpfen, z. B. Philo nicht logie.

    Klammern

    Verknüpfungen können Sie mit Klammern voneinander trennen, z. B. (Philo nicht logie) oder (Psycho und logie).

    Wortgruppen

    Zusammenhängende Worte werden als Wortgruppe gesucht, wenn Sie sie in Anführungsstriche setzen, z. B. „Bundesrepublik Deutschland“.

    Auswahlkriterien

    Die Erweiterte Suche können Sie auch nutzen, ohne Suchbegriffe einzugeben. Sie orientiert sich dann an den Kriterien, die Sie ausgewählt haben (z. B. nach dem Land oder dem Sachgebiet).

    Haben Sie in einer Kategorie kein Kriterium ausgewählt, wird die gesamte Kategorie durchsucht (z.B. alle Sachgebiete oder alle Länder).