idw – Informationsdienst Wissenschaft

Nachrichten, Termine, Experten

Grafik: idw-Logo
Grafik: idw-Logo

idw - Informationsdienst
Wissenschaft

Science Video Project
idw-Abo

idw-News App:

AppStore

Google Play Store



Instance:
Share on: 
07/13/2020 11:35

Electron cryo-microscopy: Using inexpensive technology to produce high-resolution images

Ronja Münch Pressestelle
Martin-Luther-Universität Halle-Wittenberg

    Biochemists at Martin Luther University Halle-Wittenberg (MLU) have used a standard electron cryo-microscope to achieve surprisingly good images that are on par with those taken by far more sophisticated equipment. They have succeeded in determining the structure of ferritin almost at the atomic level. Their results were published in the journal "PLOS ONE".

    Electron cryo-microscopy has become increasingly important in recent years, especially in shedding light on protein structures. The developers of the new technology were awarded the Nobel Prize for Chemistry in 2017. The trick: the samples are flash frozen and then bombarded with electrons. In the case of traditional electron microscopy, all of the water is first extracted from the sample. This is necessary because the investigation takes place in a vacuum, which means water would evaporate immediately and make imaging impossible. However, because water molecules play such an important role in biomolecules, especially in proteins, they cannot be examined using traditional electron microscopy. Proteins are among the most important building blocks of cells and perform a variety of tasks. In-depth knowledge of their structure is necessary in order to understand how they work.

    The research group led by Dr Panagiotis Kastritis, who is a group leader at the Centre for Innovation Competence HALOmem and assistant professor at the Institute of Biochemistry and Biotechnology at MLU, acquired a state-of-the-art electron cryo-microscope in 2019. "There is no other microscope like it in Halle," says Kastritis. The new "Thermo Fisher Glacios 200 kV", financed by the Federal Ministry of Education and Research, is not the best and most expensive microscope of its kind. Nevertheless, Kastritis and his colleagues succeeded in determining the structure of the iron storage protein apoferritin down to 2.7 ångströms (Å), in other words, almost down to the individual atom. One ångström equals one-tenth of a nanometre. This puts the research group in a similar league to departments with far more expensive equipment. Apoferritin is often used as a reference protein to determine the performance levels of corresponding microscopes. Just recently, two research groups broke a new record with a resolution of about 1.2 Å. "Such values can only be achieved using very powerful instruments, which only a handful of research groups around the world have at their disposal. Our method is designed for microscopes found in many laboratories," explains Kastritis.

    Electron cryo-microscopes are very complex devices. "Even tiny misalignments can render the images useless," says Kastritis. It is important to programme them correctly and Halle has the technical expertise to do this. But the analysis that is conducted after the data has been collected is just as important. "The microscope produces several thousand images," explains Kastritis. Image processing programmes are used to create a 3D structure of the molecule. In cooperation with Professor Milton T. Stubbs from the Institute of Biochemistry and Biotechnology at MLU, the researchers have developed a new method to create a high-resolution model of a protein. Stubbs’ research group uses X-ray crystallography, another technique for determining the structure of proteins, which requires the proteins to be crystallised. They were able to combine a modified form of an image analysis technique with the images taken with the electron cryo-microscope. This made charge states and individual water molecules visible.

    "It’s an attractive method," says Kastritis. Instead of needing very expensive microscopes, a lot of computing capacity is required, which MLU has. Now, in addition to using X-ray crystallography, electron cryo-microscopy can be used to produce images of proteins - especially those that are difficult to crystallise. This enables collaboration, both inside and outside the university, on the structural analysis of samples with medical and biotechnological potential.


    Contact for scientific information:

    Assistant Professor Panagiotis Kastritis
    Institute of Biochemistry and Biotechnology
    ZIK HALOmem "membrane structures and dynamics"
    phone: +49 345 55-24983
    email: panagiotis.kastritis@bct.uni-halle.de
    web: https://blogs.urz.uni-halle.de/kastritislab/


    Original publication:

    Hamdi, Farzad et al. 2.7 Å cryo-EM structure of vitrified M. musculus H-chain apoferritin from a compact 200 keV cryo-microscope. PLOS ONE (2020). https://doi.org/10.1371/journal.pone.0232540


    Images

    Part of the 3D-structure of apoferritin
    Part of the 3D-structure of apoferritin
    Panagiotis Kastritis


    Criteria of this press release:
    Business and commerce, Journalists, Scientists and scholars
    Biology
    transregional, national
    Research results, Transfer of Science or Research
    English


     

    Help

    Search / advanced search of the idw archives
    Combination of search terms

    You can combine search terms with and, or and/or not, e.g. Philo not logy.

    Brackets

    You can use brackets to separate combinations from each other, e.g. (Philo not logy) or (Psycho and logy).

    Phrases

    Coherent groups of words will be located as complete phrases if you put them into quotation marks, e.g. “Federal Republic of Germany”.

    Selection criteria

    You can also use the advanced search without entering search terms. It will then follow the criteria you have selected (e.g. country or subject area).

    If you have not selected any criteria in a given category, the entire category will be searched (e.g. all subject areas or all countries).