New test procedure for developing quick-charging lithium-ion batteries

Dipl.-Biologin Annette Stettien Unternehmenskommunikation
Forschungszentrum Jülich

    Jülich / Munich, 6 December 2017 - When lithium-ion batteries are charged too quickly, metallic lithium gets deposited on the anodes. This reduces battery capacity and lifespan and can even destroy the batteries. Scientists at the Forschungszentrum Jülich and the Technical University of Munich (TUM) have now presented a process that, for the first time ever, allows this so-called lithium plating process to be investigated directly. This puts new strategies for quick-charging strategies close at hand.

    Lithium plating, the depositing of metallic lithium at the anodes of lithium-ion batteries, is one of the primary factors that limits charging current. The performance of batteries suffers significantly from these metallic deposits. In extreme cases this can result in short circuits and even batteries going up in flames.

    When charging batteries, the positively charged lithium ions move through the liquid electrolytes and are deposited in the porous graphite anodes. However, the larger the current and the lower the temperature, the greater the probability that the lithium ions will not be deposited within the electrodes, as desired, but rather as a solid metallic layer on the outer surface.

    Indirect evidence does not serve the goal

    Even though this phenomenon is basically well-known, many aspects remain shrouded in mystery. Until now, it was not possible to directly observe how and under which circumstances lithium plating takes place. “Using traditional methods of microscopy, we can only observe a battery after the fact, because it needs to be cut open,” explains Dr. Josef Granwehr at the Jülich Institute of Energy and Climate Research (IEK-9). “In the process, further reactions that distort the results become inevitable.”

    Even highly developed processes like neutron scattering allow for only indirect analyses. Compounding the problem is the fact that available slots for measurements at research reactors and large particle accelerators are scarce. This makes these tools more suitable for fundamental investigations than for tedious, practical test series.

    Electrons show the way

    The electron paramagnetic resonance (EPR) spectroscopy process presented in the renowned scientific journal Materials Today, on the other hand, can be readily integrated into laboratory procedures – with only moderate investment. The method is akin to the better-known nuclear magnetic resonance (NMR) spectroscopy, albeit focusses on electron spins rather than atomic nuclei.

    “Electrons are placed in an externally applied, static magnetic field,” explains Granwehr. Unpaired electrons in the sample are “sounded out” using microwaves. In the magnetic field, these stimulate the electrons to flip, which can be measured via the associated drop in microwave radiation intensity. EPR can differentiate between metallic lithium plating and lithium embedded in the graphite anodes.

    The test cell is the key

    “The key to detecting lithium plating using EPR was the construction of a test cell compatible with the requirements of EPR spectroscopy while at the same time exhibiting good electrochemical properties,” explains lead author Dr. Johannes Wandt. “The geometry is also important. Precise measurement results are contingent on the sample being exposed to the magnetic field but not the inevitably present electric field.”
    To ensure this, Wandt developed a rod-shaped cell while he was a doctoral candidate in the group of Prof. Hubert A. Gasteiger (Chair of Technical Electrochemistry) at TUM that allows the formation of metallic lithium to be detected directly and with quantitative precision.

    The right strategy for quick charging

    “Using this process, it is now for the first time possible to investigate lithium plating and the associated processes in a differentiated manner that is relevant to a whole array of applications,” explains Rüdiger-A. Eichel, a director at the Jülich Institute of Energy and Climate Research (IEK-9). “One example is the development of safe and at the same time fast charging protocols. Our process make determining the maximum charging current before lithium plating sets in possible, as well as ascertaining other boundary conditions like temperature and the influence of electrode geometry.”

    Beyond this, the methodology is well suited as a test procedure for a variety of battery materials, for example the development of new admixtures that suppress lithium plating.

    The research was funded by the German Federal Ministry of Education and Research (BMBF) in the context of the ExZellTUM II project and the Bavarian State Ministry of Economic Affairs and Media, Energy and Technology in the context of the EEBatt project. The EEBatt project is part of the “TUM.Energy” priority program coordinated by the Munich School of Engineering (MSE).

    Original publication:
    Johannes Wandt, Peter Jakes, Josef Granwehr, Rüdiger-A. Eichel, Hubert A. Gasteiger
    Quantitative and Time Resolved Detection of Lithium Plating on Graphite Anodes in Lithium Ion Batteries

    Contact:

    Prof. Dr. Josef Granwehr
    Institute of Energy- und Climate Research, Fundamental Electrochemistry (IEK-9)
    Tel.: +49-2461 61-96400
    E-Mail: j.granwehr@fz-juelich.de

    Prof. Dr. Rüdiger-A. Eichel
    Director Institute of Energy- und Climate Research, Fundamental Electrochemistry (IEK-9)
    Tel.: +49 2461 61-5124
    E-Mail: Sekretariat-Eichel@fz-juelich.de

    Dr. Johannes Wandt
    E-Mail: johannes.wandt@tum.de

    Press contact:

    Dr. Regine Panknin
    Forschungszentrum Jülich, Corporate communications
    Tel. 02461 61-9054
    E-Mail: r.panknin@fz-juelich.de

    Tobias Schlößer
    Forschungszentrum Jülich, Corporate communications
    Tel. 02461 61-4771
    E-Mail: t.schloesser@fz-juelich.de


    Weitere Informationen:

    http://www.fz-juelich.de/SharedDocs/Pressemitteilungen/UK/EN/2017/2017-12-06-lit... - Pressemitteilung


    Bilder

    Test cell for lithium ion batteries
    Test cell for lithium ion batteries
    Forschungszentrum Jülich / T. Schlößer
    None

    Analysis of a test cell with EPR spektroskopy
    Analysis of a test cell with EPR spektroskopy
    Forschungszentrum Jülich / T. Schlößer
    None


    Merkmale dieser Pressemitteilung:
    Journalisten
    Chemie, Energie, Physik / Astronomie, Verkehr / Transport, Werkstoffwissenschaften
    überregional
    Forschungs- / Wissenstransfer, Forschungsergebnisse
    Englisch


     

    Test cell for lithium ion batteries


    Zum Download

    x

    Analysis of a test cell with EPR spektroskopy


    Zum Download

    x

    Hilfe

    Die Suche / Erweiterte Suche im idw-Archiv
    Verknüpfungen

    Sie können Suchbegriffe mit und, oder und / oder nicht verknüpfen, z. B. Philo nicht logie.

    Klammern

    Verknüpfungen können Sie mit Klammern voneinander trennen, z. B. (Philo nicht logie) oder (Psycho und logie).

    Wortgruppen

    Zusammenhängende Worte werden als Wortgruppe gesucht, wenn Sie sie in Anführungsstriche setzen, z. B. „Bundesrepublik Deutschland“.

    Auswahlkriterien

    Die Erweiterte Suche können Sie auch nutzen, ohne Suchbegriffe einzugeben. Sie orientiert sich dann an den Kriterien, die Sie ausgewählt haben (z. B. nach dem Land oder dem Sachgebiet).

    Haben Sie in einer Kategorie kein Kriterium ausgewählt, wird die gesamte Kategorie durchsucht (z.B. alle Sachgebiete oder alle Länder).