Laser-based X-ray Imaging Picks Up Speed

Dr. Olivia Meyer-Streng Presse und Öffentlichkeitsarbeit
Max-Planck-Institut für Quantenoptik

    Using a novel, laser-based X-ray technique, laser physicists in Garching have imaged a bone sample in three dimensions by microtomography within minutes, thus taking a significant step towards the medical application of the technology.

    Researchers from Ludwig-Maximilians-Universität (LMU), the Max Planck Institute of Quantum Optics (MPQ) and the Technical University of Munich (TUM) have taken a major step towards the clinical application of a new laser-based source of X-rays. They recently demonstrated that the instrument enables the tomographic reconstruction of the three-dimensional fine structure of a bone sample within a few minutes. Up to now, laser-based measurements of this sort took several hours. The breakthrough was made possible by the further development of ATLAS, the high-performance laser in LMU’s Laboratory for Extreme Photonics (LEX Photonics) der LMU on the Research Campus in Garching. Reconstruction of the sample from the imaging data was also facilitated by the use of specially designed computer programmes.

    The X-rays used for medical imaging or to inspect the contents of passengers’ baggage at airports are produced by X-ray tubes, whose design has remained essentially unchanged for over a century. Research scientists prefer to use what is known as synchrotron radiation as an X-ray source. Synchrotron radiation is many times brighter and thus allows one to carry out far more detailed structural analyses. However, sources of synchrotron radiation are relatively thin on the ground, as its generation requires the acceleration of electrons to ultrarelativistic velocities (speeds approaching that of light), and construction of particle accelerators of the necessary size is immensely costly.

    To harness the advantages of synchrotron radiation for general use in medicine, physicists at LMU, the MPQ and the TUM have been exploring the application of high-performance lasers to the production of X-rays. In their set-up, hydrogen atoms are irradiated with extremely intense pulses of laser light. The highly energetic optical fields strip the electrons from the atoms and part of the ionized plasma electrons are accelerated. Simultaneously, these electrons oscillate in the plasma fields, which causes them to emit the desired synchrotron radiation, i.e. high-intensity X-rays. Moreover, this whole process takes place over a path-length of less than 15 mm. So laser-based X-ray sources have a far smaller footprint, and are much less expensive to build, than conventional synchrotrons, but produce X-radiation of comparable quality.

    In the early trials carried out at the Max Planck Institute in 2015, the research team was able to derive the three-dimensional structure of an insect from two-dimensional projection images taken from different angles. For the latest experiments, performed in the Laboratory for Extreme Photonics, Prof. Stefan Karsch and his colleagues have boosted the pulse rate, photon yield and photon energies, and this time they chose to image a sample of human bone. Thanks to an improved processing algorithm, developed by Prof. Franz Pfeiffer and his group at the TUM, the team needed to collect significantly less data than before. Accordingly, the complete tomogram could be obtained within less than three minutes.

    The project was conceived and initiated in the Munich-Centre for Advanced Photonics (a Cluster of Excellence) and is undergoing further development at the Center for Advanced Laser Applications (CALA) in Garching. The laser systems available at CALA are expected to significantly enhance the efficiency of the source and the quality of the radiation generated, thus making this new form of tomography available for clinical applications for the first time. Thorsten Naeser

    Figure caption:
    The further development of ATLAS, the high-performance laser in LMU’s Laboratory for Extreme Photonics, paved the way for the tomographic reconstruction of the three-dimensional fine structure of a bone sample within a few minutes. (Photo: Thorsten Naeser)

    Original publications:

    A.Döpp, L. Hehn, J. Götzfried, J. Wenz, M. Gilljohann, H. Ding, S. Schindler, F. Pfeiffer, and S. Karsch
    Quick X-ray microtomography using a laser-driven betatron source
    Optica Vol. 5, Issue 2, pp. 199-203 (2018) doi.org/10.1364/OPTICA.5.000199

    J.Götzfried, A.Döpp, M.Gilljohann, H.Ding, S.Schindler, J.Wenz, L.Hehn, F.Pfeiffer, S.Karsch
    Research towards high-repetition rate laser-driven X-ray sources for imaging applications
    Nuclear Instruments and Methods A (2018), doi.org/10.1016/j.nima.2018.02.110

    Contacts:

    Dr. Andreas Döpp
    Ludwig-Maximilians-Universität München
    Chair of Experimental Physics-Laser Physics
    85748 Garching, Germany
    Phone: +49 (0)89 289 - 14170
    E-mail: a.doepp@physik.uni-muenchen.de

    Dr. Olivia Meyer-Streng
    Press & Public Relations
    Max Planck Institute of Quantum Optics
    85748 Garching, Germany
    Phone: +49 (0)89 / 32 905 - 213
    E-mail: olivia.meyer-streng@mpq.mpg.de


    Bilder

    see "Figure caption" below the text
    see "Figure caption" below the text
    Photo: Thorsten Naeser
    None


    Merkmale dieser Pressemitteilung:
    Journalisten, jedermann
    Physik / Astronomie
    überregional
    Forschungsergebnisse, Wissenschaftliche Publikationen
    Englisch


     

    see "Figure caption" below the text


    Zum Download

    x

    Hilfe

    Die Suche / Erweiterte Suche im idw-Archiv
    Verknüpfungen

    Sie können Suchbegriffe mit und, oder und / oder nicht verknüpfen, z. B. Philo nicht logie.

    Klammern

    Verknüpfungen können Sie mit Klammern voneinander trennen, z. B. (Philo nicht logie) oder (Psycho und logie).

    Wortgruppen

    Zusammenhängende Worte werden als Wortgruppe gesucht, wenn Sie sie in Anführungsstriche setzen, z. B. „Bundesrepublik Deutschland“.

    Auswahlkriterien

    Die Erweiterte Suche können Sie auch nutzen, ohne Suchbegriffe einzugeben. Sie orientiert sich dann an den Kriterien, die Sie ausgewählt haben (z. B. nach dem Land oder dem Sachgebiet).

    Haben Sie in einer Kategorie kein Kriterium ausgewählt, wird die gesamte Kategorie durchsucht (z.B. alle Sachgebiete oder alle Länder).