05.04.2022 14:06

Technical rules and regulations impart knowledge and promote confidence in optical coherence tomography

Susanne Krause Externe und interne Kommunikation
Fraunhofer-Institut für Produktionstechnologie IPT

    Optical coherence tomography (OCT) is a new imaging technique that generates high-resolution cross-sectional images of transparent and semitransparent media. It is used both in industrial metrology, for example in component monitoring, and in biomedical diagnostics, such as ophthalmology or tissue diagnostics. Companies and research institutes focusing on industrial metrology and medical technology also expect a wide range of other fields of application. They cooperate in the VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik (GMA) in an expert committee on OCT and have now published a first draft guideline with standardized process descriptions.

    Bringing together expertise from industry and research to jointly publish a standardized set of rules for OCT and thus open the way for further OCT application fields in the future - that is the goal of GMA's Technical Committee 8.19 "Optical Coherence Tomography". This is because the comparatively new measurement method has not yet been described in a generally valid manner, and various procedures and performance characteristics have not yet been standardized. Thus, the comparability of different OCT systems is not yet given and a wider dissemination is limited. This is to change through the guideline work of the technical committee: "Knowledge of and confidence in OCT are to be promoted through a general technical set of rules. To this end, we have now defined terms and measurement methods for performance parameters and described typical process variants as a first step," explains Niels König, head of the Production Measurement Technology department at the Fraunhofer IPT and chairman of the expert committee.

    Non-contact and high-resolution imaging - from biomedicine to industry

    Originally used in ophthalmology, OCT is a measurement technique based on short-coherent interferometry for non-contact and high-resolution imaging of tomographic cross-sectional images. It has a penetration depth of several millimeters and a resolving power in the single-digit micrometer range. In medical diagnostics, OCT can be used to examine organic tissue, such as tumor tissue, at a very early stage of disease, either intraoperatively or in vitro. But OCT is also used in industry thanks to its universal properties in material and defect testing, for example in plastic products. In the case of opaque materials into which the light cannot penetrate, for example metal, OCT is used for surface and distance measurement.

    Now, the first work results of the new technical committee on OCT are available in the form of the draft guideline VDI/VDE 5565 Part 1. The draft describes the OCT procedures and defines the necessary terms. In order to reach as much of the OCT community as possible, the draft has already been published bilingually in German and English. The draft can be commented on by objection until July 31, 2022. After the objections have been dealt with, the valid guideline will then be published. The committee is already working on VDI/VDE 5565 Part 2 on "Signal processing and data evaluation". The metrological characterization of OCT systems is on the roadmap for further guideline projects.

    For further information, please contact the GMA office:

    VDI/VDE Society
    Measurement and automation technology (GMA)
    Erik Marquardt
    Phone +49 211 6214-373
    marquardt@vdi.de
    www.vdi.de/5565


    Wissenschaftliche Ansprechpartner:

    Dipl.-Phys. Niels König
    Head of department "Production metrology"

    Fraunhofer Institute for Production Technology IPT
    Steinbachstr. 17
    52074 Aachen, Germany
    Phone +49 241 8904-113
    niels.koenig@ipt.fraunhofer.de
    www.ipt.fraunhofer.de


    Weitere Informationen:

    https://www.ipt.fraunhofer.de/en/Press/Pressreleases/220328-technical-rules-and-...


    Bilder

    First OCT guideline proposal with standardized procedure descriptions.
    First OCT guideline proposal with standardized procedure descriptions.

    © Fraunhofer IPT


    Merkmale dieser Pressemitteilung:
    Journalisten, Wirtschaftsvertreter, Wissenschaftler
    Biologie, Elektrotechnik, Maschinenbau, Medizin, Werkstoffwissenschaften
    überregional
    Forschungs- / Wissenstransfer, Kooperationen
    Englisch


     

    Hilfe

    Die Suche / Erweiterte Suche im idw-Archiv
    Verknüpfungen

    Sie können Suchbegriffe mit und, oder und / oder nicht verknüpfen, z. B. Philo nicht logie.

    Klammern

    Verknüpfungen können Sie mit Klammern voneinander trennen, z. B. (Philo nicht logie) oder (Psycho und logie).

    Wortgruppen

    Zusammenhängende Worte werden als Wortgruppe gesucht, wenn Sie sie in Anführungsstriche setzen, z. B. „Bundesrepublik Deutschland“.

    Auswahlkriterien

    Die Erweiterte Suche können Sie auch nutzen, ohne Suchbegriffe einzugeben. Sie orientiert sich dann an den Kriterien, die Sie ausgewählt haben (z. B. nach dem Land oder dem Sachgebiet).

    Haben Sie in einer Kategorie kein Kriterium ausgewählt, wird die gesamte Kategorie durchsucht (z.B. alle Sachgebiete oder alle Länder).